Vibration monitoring basics for maintenance teams

Vibration is the most informative single measurement available on rotating equipment, because almost every mechanical fault changes how the machine moves. The subject has a reputation for being specialist, and the deeper analysis genuinely is, but the basic principles are accessible to any maintenance team and catch most of what matters.

What is being measured

Three quantities describe the same motion. Displacement is how far the machine moves, velocity is how fast, and acceleration is how rapidly that speed changes.

Displacement is most useful at low frequencies and is the normal measurement for slow machines and for shaft movement inside bearings.

Velocity, measured in millimetres per second, is the general purpose measurement for industrial machinery in the normal speed range, and it is what most overall vibration meters report. It correlates well with fatigue damage, which is why standards are written in these units.

Acceleration is most sensitive at high frequencies and is the measurement of choice for rolling element bearing defects and gear mesh problems, which produce small but rapid motion.

A single overall velocity reading tells you the machine has changed. Frequency analysis tells you what changed.

The frequency fingerprint

Most common faults produce vibration at a characteristic multiple of shaft speed, and that relationship is what makes diagnosis possible.

Imbalance produces vibration at exactly one times running speed, predominantly in the radial direction, with a steady phase relationship. It is the most common fault and the easiest to correct.

Misalignment produces vibration at two times running speed, with a significant axial component. Axial vibration above roughly half the radial level is a strong indicator.

Mechanical looseness produces a series of harmonics at one, two, three times running speed and beyond, often with half order components as well. The spectrum looks cluttered rather than having one dominant peak.

Bearing defects produce vibration at frequencies that are non integer multiples of shaft speed, calculated from the bearing geometry. These are low in amplitude initially and appear at high frequency, which is why acceleration measurement and envelope techniques detect them earlier than velocity does.

Gear problems produce vibration at the tooth mesh frequency, which is the number of teeth multiplied by shaft speed, with sidebands spaced at shaft speed when a specific tooth is damaged.

Electrical faults in motors produce vibration at twice supply frequency, which on a 50 hertz supply is 100 hertz, and this is distinguishable from mechanical causes because it disappears the instant power is removed while mechanical vibration decays as the machine coasts.

How bearing failure progresses

Rolling element bearings fail in a predictable sequence, and understanding it explains why early detection is possible.

In the first stage, a subsurface crack forms and produces very high frequency energy, typically above 20 kilohertz, detectable only by ultrasonic or specialised techniques. Nothing is audible and overall vibration is unchanged. This stage may represent a substantial part of the remaining life.

In the second stage, the defect reaches the surface and begins to produce ringing at bearing natural frequencies, in the range of a few kilohertz. Envelope or demodulation analysis detects it clearly. Overall velocity is still normal.

In the third stage, discrete defect frequencies and their harmonics appear in the spectrum, the bearing becomes audibly rough and temperature begins to rise. Remaining life is now limited and replacement should be scheduled.

In the fourth stage, the defect frequencies are replaced by a raised noise floor as the damage spreads, overall vibration rises sharply and failure is imminent. At this point the machine should not be relied upon.

The practical consequence is that a programme relying only on overall velocity detects bearing problems in stage three, which still gives useful warning but far less than envelope analysis would.

Taking readings that mean something

Consistency matters more than precision. A reading taken at a slightly different point, with a different mounting method or at a different load, is not comparable with the previous one.

Fix the measurement locations physically, with a marked spot or a permanently mounted stud. Magnetic mounting is acceptable for general trending but reduces the usable frequency range, and hand held probes are worse still, particularly at high frequencies where bearing information lives.

Measure in three directions at each bearing, horizontal, vertical and axial, because the relationship between them is diagnostic. Imbalance shows radially, misalignment shows axially.

Record the operating conditions. Speed, load and temperature all affect vibration, and a reading taken at half load is not comparable with one taken at full load.

Interpreting levels

ISO 10816 and its successors give broad guidance on acceptable overall velocity by machine size and mounting rigidity, dividing results into zones from newly commissioned condition through acceptable long term operation to unacceptable.

These are useful as a sanity check, and they are far less useful than a trend on the specific machine. A pump that has always run at 4 millimetres per second and still does is fine. One that ran at 1.5 for three years and now reads 3 has a developing problem, even though 3 is within an acceptable band.

Establish a baseline when the machine is known to be in good condition, ideally shortly after commissioning or after a major overhaul, and judge everything against it.

Starting a programme without a large investment

Choose the machines first. The ones whose failure stops production, or which have a history of failures, or which are expensive to repair.

A basic route of monthly overall velocity readings on those machines, recorded consistently, costs very little and identifies developing problems. Adding a handheld analyser capable of showing a spectrum extends the capability considerably for a modest cost.

Combine it with temperature readings taken at the same time. The two measurements together are far more informative than either alone, because a rise in both points clearly at bearings while a rise in vibration alone points at balance, alignment or looseness.

Write down what was done when a problem was found and confirmed. A record of which spectrum pattern corresponded to which actual fault is how a team builds real diagnostic skill, and it is the part that is almost never kept.

Knowing the limits

Vibration monitoring does not detect everything. Electrical winding faults, lubrication contamination, and gradual efficiency loss all need other methods.

It also does not replace judgement. A rising trend indicates change, not necessarily urgency, and shutting a machine down on a single reading without confirming it wastes production. Confirm, investigate, then schedule.