Shaft alignment mistakes that destroy couplings and bearings

A flexible coupling accommodates misalignment, which is exactly why misalignment persists. The coupling absorbs the error quietly, transmits the resulting cyclic load into the bearings at each end, and the motor fails eighteen months later for reasons that get recorded as bearing quality.

The two kinds of error

Offset misalignment, sometimes called parallel misalignment, exists when the two shaft centrelines are parallel but not coincident. Angular misalignment exists when the centrelines meet at an angle. Real installations almost always have both, in both the horizontal and vertical planes, which is why alignment is a four measurement problem rather than a two measurement one.

Both produce a cyclic load at twice shaft speed, because each shaft passes through the point of maximum deflection twice per revolution. That frequency is the fingerprint used to identify misalignment in vibration analysis.

Believing the coupling will absorb it

Coupling manufacturers publish maximum permitted misalignment, and that figure is routinely used as an alignment target. It is not a target, it is a limit beyond which the coupling itself is damaged.

Operating at the coupling limit transmits substantial load into the bearings continuously. Good practice aligns to a small fraction of the coupling capability, typically measured in hundredths of a millimetre for a machine running at 1500 revolutions per minute, with tighter tolerance as speed rises.

Elastomeric couplings hide the problem best and therefore cause the most damage, because there is no obvious symptom until the element fails.

Aligning cold and forgetting thermal growth

A pump handling hot fluid, a compressor, a fan on hot gas or a motor itself all grow as they reach operating temperature. A machine aligned perfectly when cold can be significantly misaligned once it is hot.

Growth is calculated from the temperature change, the height from the mounting feet to the shaft centreline and the thermal expansion coefficient of the material. The correction is applied as a deliberate cold offset, so that the machine comes into alignment at working temperature.

Ignoring this is very common on pumps handling anything above ambient. Manufacturers usually publish the expected growth figures, and where they do not, a measurement of casing temperature after a few hours of running allows a reasonable estimate.

Soft foot

Soft foot exists when a machine does not sit evenly on its four mounting points, so tightening the bolts distorts the frame. It comes in two forms. Parallel soft foot, where one foot is simply shorter than the others, and angular soft foot, where a foot is not parallel to the baseplate.

The consequence is that the bearing housings are pulled out of line by the act of bolting down, so no amount of shimming in the vertical direction will produce a stable alignment. It also distorts the stator bore in a motor, which can change the air gap.

The check is straightforward. With all bolts tight, loosen one at a time and measure the movement of the foot with a dial indicator. Anything above about 0.05 millimetres needs correcting with shims before alignment begins.

Soft foot must be corrected first. Attempting alignment on a machine with soft foot produces readings that change every time the bolts are touched.

Pipe strain

On pumps, the pipework frequently pulls the casing out of position. If a flange has to be forced into place with bolts, that force remains in the assembly and moves the pump relative to the motor.

The test is to align the machine, then loosen the suction and discharge flanges and watch the dial indicators. Movement means the pipework is imposing load, and the pipework needs supporting or adjusting rather than the alignment being redone.

Pipe strain also distorts the pump casing itself, which affects internal clearances and seal life independently of alignment.

Shimming badly

A stack of many thin shims behaves like a spring and settles over time. Good practice uses as few shims as possible, generally no more than three or four under any foot, with the thickest at the bottom.

Shims must be clean, flat, free of burrs and large enough to support the whole foot. Rusty or damaged shims introduce their own soft foot. Cutting shims from sheet on site produces burred edges that compress unevenly.

Stainless steel pre cut shims cost little and remove an entire category of problem.

Moving the wrong machine

The convention is to align the movable machine, normally the motor, to the fixed machine, normally the pump or gearbox. Attempting to move the driven machine usually means disturbing pipework or a fixed drive connection, and it is far more work.

The related error is correcting only in the vertical plane with shims and then forcing horizontal correction by hammering. Jacking bolts, where fitted, should be used, and where they are not fitted they are worth adding to any machine that is realigned more than once.

Measurement method and its limits

A straight edge and feeler gauge detects gross errors only and is not adequate for anything above a few hundred revolutions per minute.

Dial indicators mounted on brackets give accurate results but require care, because bracket sag introduces a systematic error that must be measured and subtracted. The sag check involves mounting the bracket on a rigid bar and rotating it, which takes a few minutes and is often skipped.

Laser alignment systems remove bracket sag entirely, calculate the required shim values directly and record results. They pay for themselves quickly on any site with a number of rotating machines, mainly through time saved rather than accuracy gained.

Recognising misalignment after the fact

Vibration at twice running speed, particularly in the axial direction, is the classic indicator. Axial vibration above about half the radial level is a strong sign.

Elastomeric coupling elements that wear or crack unevenly, rubber dust around the coupling guard, and bearings at the coupling end of both machines running hotter than the outboard bearings all point the same way.

Repeated bearing failures at the same position on the same machine are the most reliable indicator of all, because a genuine bearing quality problem would not select the same position every time.

What good practice looks like

Check and correct soft foot before starting. Check for pipe strain on anything connected to piping. Calculate thermal growth and set the cold offset deliberately. Align to a fraction of the coupling limit rather than to the limit. Record the final readings so that the next person has a reference.

The whole exercise takes an hour or two on a typical machine. A motor rewind and the production stop that goes with it take considerably longer.